DWL@DWL10000390405
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.16.0.0 | * | 18.07.2023 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.16.0.0: ID: 772435 Continuous product improvement Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(436), 1\9843_3.fw(436), 1\9843_4.fw(436), 1\9843_5.fw(436), 1\9843_6.fw(436), 1\9843_7.fw(436) Version 2.15.0.0: ID: 758750 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(433), 1\9843_3.fw(433), 1\9843_4.fw(433), 1\9843_5.fw(433), 1\9843_6.fw(433), 1\9843_7.fw(433) Version 2.14.0.0: ID: 736520 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 736555 NUMBER:JACK improved ISN (TCP startsequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(432), 1\9843_3.fw(432), 1\9843_4.fw(432), 1\9843_5.fw(432), 1\9843_6.fw(432), 1\9843_7.fw(432) Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.2.0: ID: 720640 Support for DNA configuration with LWL hub's Channel description changed: No Configuration description changed:Yes Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.1.0: ID: 695165 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configurationdescription changed: Yes Firmware changed: No ID: 695465 Module documentation revised Data sheet V2.39 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO moduleFALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registerswith AsIOAcc while ModuleOk = FALSE prevents module from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427),1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedurefor hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID:400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problemalso occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginningwith HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / SupportID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID:246550 DNA support; Update behavior on X2X bus of the BC improved -DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number ofconfiguration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.15.0.0 | * | 13.10.2022 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.15.0.0: ID: 758750 Optimization of asynchronous register access Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(433), 1\9843_3.fw(433), 1\9843_4.fw(433), 1\9843_5.fw(433), 1\9843_6.fw(433), 1\9843_7.fw(433) Version 2.14.0.0: ID: 736520 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affectedby a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 736555 NUMBER:JACK improved ISN (TCP start sequence) generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(432), 1\9843_3.fw(432), 1\9843_4.fw(432), 1\9843_5.fw(432), 1\9843_6.fw(432), 1\9843_7.fw(432) Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.2.0: ID: 720640 Support for DNA configuration with LWL hub's Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.1.0: ID: 695165 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 695465 Module documentation revised Data sheet V2.39 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding forthe next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the buscoupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419),1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 /Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed:No Firmware changed: Yes ID: 468050 optimization of X2X FWupdates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd doesnot change, when empty backplanes are addedor removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to thebuscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple AsynchronousSend' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions andBugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPUdid a warmstart (A&P 211805) - Activation of MultipleRead/Write featurefor faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operationin Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with thesame node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.14.0.0 | * | 18.10.2021 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.14.0.0: ID: 736520 POWERLINK Security Vulnerability (CVE-2020-13987 & CVE-2020-17438) POWERLINK Security Vulnerability (CVE-2020-13987) The POWERLINK IP stack was affected by a security vulnerability impacting thechecksum calculation of TCP/UDP packets. POWERLINK Security Vulnerability (CVE-2020-17438) The POWERLINK IP stack was affected by a security vulnerability impacting fragmented packet reassembly. Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 736555 NUMBER:JACK improved ISN (TCP start sequence)generation in IP stack Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(432), 1\9843_3.fw(432), 1\9843_4.fw(432), 1\9843_5.fw(432), 1\9843_6.fw(432), 1\9843_7.fw(432) Version 2.12.0.0: ID: Adaptations forAutomation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.2.0: ID: 720640 Support for DNA configuration with LWL hub's Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.1.0: ID: 695165 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 695465 Module documentation revised Data sheet V2.39 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching huboff again Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler notworking in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 /Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID:400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change,when empty backplanes are addedor removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot ofbus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785/ Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmwareupdate of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/Oconstellations, the X2X modules don't start Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for anew firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.12.0.0 | * | 23.07.2021 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.12.0.0: ID: Adaptations for Automation Studio 4.11 Channel description changed: no Configuration description changed: yes Firmware changed: no Version 2.11.2.0: ID: 720640 Support for DNA configuration with LWL hub's Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.1.0: ID: 695165 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 695465 Module documentation revised Data sheet V2.39 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not goinginto Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115,400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection withPLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 Whencombining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channeldescription changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restartingthe boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does notwork in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164),1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2Xconfigurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 forsignal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed:No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance onthe network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware:1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.11.2.0 | * | 02.04.2021 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.11.2.0: ID: 720640 Support for DNA configuration with LWL hub's Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.1.0: ID: 695165 Support for automatic DNA configuration from AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 695465 Module documentation revised Data sheet V2.39 Channel descriptionchanged: No Configuration description changed: No Firmware changed:No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end stationswitching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045/ Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413),1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / SupportID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic datapoint "StationAtBusEnd" die not change. The data point die change when IOModules were removed or added. A new handshake between Automation Runtime andfirmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165),1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base moduleX20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work Invery rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.11.1.0 | * | 24.08.2020 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.11.1.0: ID: 695165 Support for automatic DNA configurationfrom AS 4.9.1 Channel description changed: No Configuration description changed: Yes Firmware changed: No ID: 695465 Module documentation revised Data sheet V2.39 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430),1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptations for Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimizationof the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmwarechanged: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730/ Support ID: 400241376 Temporary toggling of data point ModuleOk if I/Omodule fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configurationdescription changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID:493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 /Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply forthe IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost Whenthere was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same nodenumber generated disturbance on the network (A&P 166040) - Functions fora new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID:164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.11.0.0 | * | 31.01.2020 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.11.0.0: ID: 664345 DNA: Hub of PLK BC active until first IDENT_REQUEST Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 664365 Adaptationsfor Automation Studio 4.8 Channel description changed: No Configuration description changed: No Firmware changed: No ID: 665745 ModuleOk of IO module FALSE after warm restart even though the module is working as expected Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 665825 Accessing non-cyclic registers with AsIOAcc while ModuleOk = FALSE preventsmodule from starting/communicating Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 666190 Module documentation revised Data sheet V2.38 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(430), 1\9843_3.fw(430), 1\9843_4.fw(430), 1\9843_5.fw(430), 1\9843_6.fw(430), 1\9843_7.fw(430) Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration descriptionchanged: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040/ Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configurationdescription changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400),1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC:StationAtBusEnd does not change, when empty backplanes are addedor removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data pointdie change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is suppliedwith power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2Xsettings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronouscommunication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlinkbuscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. <G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurationsdon't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus ofthe BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.10.0.0 | * | 10.07.2019 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.10.0.0: ID: 647930 Optimization of the firmware update process Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(428), 1\9843_3.fw(428), 1\9843_4.fw(428), 1\9843_5.fw(428), 1\9843_6.fw(428), 1\9843_7.fw(428) Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address the CN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases ifpoll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID:574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safetymodules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connectionwith PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Moduledocumentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connectionis available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on theend of the X2XLink thediagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the"StationAtBusEnd" faster. The same problem also occurs with modules where theX2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmwarechanged: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed:No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) -Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed:No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.9.0.0 | * | 01.03.2019 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.9.0.0: ID: 624090 Optimization of hub behavior Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629005 Ring redundancy: Cannot address theCN that closes the ring Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629070 DNA: BC as head-end station switching hub off again Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 629155 Shortened preamble of Ethernet frame leading to incorrectly detected CRC errors Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(427), 1\9843_3.fw(427), 1\9843_4.fw(427), 1\9843_5.fw(427), 1\9843_6.fw(427) Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputsof I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup timeoptimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID:400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-oncycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of theX2XLink thediagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink issupplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could beaccored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication causedthe safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID:277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferredvia IdentResponse in the first 4 bytes of the field VendorSpecificExt1 -Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activationof MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.8.0.0 | * | 05.12.2018 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.8.0.0: ID: 619135 / Support ID: 400257683 DNA: PLK hub forwarding for the next node not enabled in rare cases Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 619175 / Support ID: 400262159 Outputs of I/O modules behind the bus coupler not working in some cases if poll-response chaining active Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(426), 1\9843_3.fw(426), 1\9843_4.fw(426), 1\9843_5.fw(426), 1\9843_6.fw(426) Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 /Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / SupportID: 400178654 Safety modules in connection with PLK BCs, with only inputdatapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2X modules isnot working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channeldescription changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 withVersion 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/Omodules behind POWERLINK bus controllers no longer achieving Operationalmodeafter multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. Thesame problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix forUp/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channeldescription changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed:Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration descriptionchanged: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.7.0.0 | * | 17.04.2018 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.7.0.0: ID: 586730 / Support ID: 400241376 Temporary toggling of data point ModuleOk if I/O module fails Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(424), 1\9843_3.fw(424), 1\9843_4.fw(424), 1\9843_5.fw(424), 1\9843_6.fw(424) Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long timetakes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415),1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, withonly input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID: 400177243 X2X FW update of several X2Xmodules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When empty backplanes are plugged or unplugged on the end of the X2XLinkthediagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accoredafter PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985/ Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163),1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channel description changed: Yes Configurationdescription changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel descriptionchanged: No Configuration description changed: No Firmware changed:Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Supportof PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filterand corrections New info-/diagnostic data points in HWC, new FW 1.39 forsignal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for a new firmware download mechanism implemented(A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |
|||||
Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
2.6.0.0 | * | 02.02.2018 | 2 MB | EXE | AS4_HW_X20BC8083.exe | |
Popis |
V4.0 HW Upgrade (X20BC8083) Revision information X20BC8083 Version 2.6.0.0: ID: 574215 Optimization of boot procedure for hardware variant 5 und 6 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(423), 1\9843_3.fw(423), 1\9843_4.fw(423), 1\9843_5.fw(423), 1\9843_6.fw(423) Version 2.5.6.0: ID: 564800 Optimization the boot up for hardware variant 5 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(422), 1\9843_3.fw(422), 1\9843_4.fw(422), 1\9843_5.fw(422) Version 2.5.5.0: ID: 551115 Startup time optimizations Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(421), 1\9843_3.fw(421), 1\9843_4.fw(421), 1\9843_5.fw(421) Version 2.5.4.0: ID: 540310 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(419), 1\9843_3.fw(419), 1\9843_4.fw(419) Version 2.5.3.0: ID: 523465 / Support ID: 400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic are booted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(417), 1\9843_3.fw(417), 1\9843_4.fw(417) Version 2.5.2.0: ID: 493880 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(415), 1\9843_3.fw(415), 1\9843_4.fw(415) Version 2.5.0.0: ID: 468040 / Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468045 / Support ID:400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468050 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468525 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(413), 1\9843_3.fw(413), 1\9843_4.fw(413) Version 2.3.0.0: ID: 460100 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460220 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 462080 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(411), 1\9843_3.fw(411), 1\9843_4.fw(411) Version 2.2.1.0: ID: 445325 / Support ID: 400162116 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 448525 / Support ID: 400164639 When combining X20BC8083 with Version 2.2.0.0 and X20HB2881 no PLK connection is available Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_2.fw(401), 1\9843_3.fw(401), 1\9843_4.fw(401) Version 2.2.0.0: ID: 439095 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439200 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(400), 1\9843_3.fw(400), 1\9843_4.fw(400) Version 2.1.0.0: ID: 404500 X2XLink-BC: StationAtBusEnd does not change,when empty backplanes are addedor removed. When empty backplanes are plugged or unplugged on the end of the X2XLink the diagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtime and firmware was implemented to update the "StationAtBusEnd" faster. The same problem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 2.0.0.0: ID: 390270 / Support ID: 400129274 Uncommon X2X settings cause permanent boot ofbus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(210), 1\9843_3.fw(210), 1\9843_4.fw(210) Version 1.3.5.0: ID: 310785/ Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311015 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9843_2.fw(168), 1\9843_3.fw(168), 1\9843_4.fw(168) Version 1.3.4.0: ID: 305150 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communication to the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(167), 1\9843_3.fw(167), 1\9843_4.fw(167) Version 1.3.3.0: ID: 298985 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmwareupdate of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmwarechanged: Yes Firmware: 1\9843_2.fw(165), 1\9843_3.fw(165), 1\9843_4.fw(165) Version 1.3.2.0: ID: 160985 Additional diagnostic data points Channel description changed: Yes Configuration description changed: No Firmware changed: No ID: 291890 / Support ID: 400087996 Error when running X20BC8083 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(164), 1\9843_3.fw(164), 1\9843_4.fw(164) Version 1.3.1.0: ID: 289015 Certain X2X configurations don't work In very rare I/Oconstellations, the X2X modules don't start Channel description changed:No Configuration description changed: No Firmware changed: Yes ID: 290080 New Hardwarevariant 4 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(163), 1\9843_3.fw(163), 1\9843_4.fw(163) Version 1.3.0.0: ID: 277175 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277745 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(160), 1\9843_3.fw(160) Version 1.2.0.0: ID: 246550 DNA support; Update behavior on X2X bus of the BC improved - DNA support (Dynamic Node Allocation) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h and 2000h/9 Channeldescription changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9843_2.fw(152), 1\9843_3.fw(152) Version 1.0.9.0: ID: 220630 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_2.fw(146) Version 1.0.8.0: ID: 218500 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(145) Version 1.0.7.0: ID: 214455 Extensions and Bugfixes - In systems with high X2X load it happened that IO modules were not restarted when the CPU did a warmstart (A&P 211805) - Activation of MultipleRead/Write feature for faster startup after configuration change - Writing to Objekt 20F0h/SubIndex 22 caused SDO errors when accessed faster than allowed - Number of configuration entries per IO module changed from 100 to 155 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(144) Version 1.0.6.0: ID: 210960 Extensions and Bugfixes - Error correction for operation in Powerlink V1 networks (A&P 210765) Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9843_1.fw(143) Version 1.0.4.0: ID: 183385 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(141) Version 1.0.3.0: ID: 173305 Extensions and Bugfixes - Improvement of X2X Timings (Jitter reduced from 180ns to 20ns) (A&P167857 und 171987) - Optimizations for operation in 200us networks - 2 nodes with the same node number generated disturbance on the network (A&P 166040) - Functions for anew firmware download mechanism implemented (A&P 168537) Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(138) Version 1.0.2.0: ID: 164665 Extensions - Extensions for operation with Safety Channeldescription changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9843_1.fw(136) |