Verze | Jazyk | Operační systém | Datum | Velikost | Typ | Stáhnout |
---|---|---|---|---|---|---|
2.5.4.0 | * | 05.07.2017 | 2 MB | EXE | AS2.6_HW_X20BC8084.exe | |
Popis |
V2.6 HW Upgrade (X20BC8084) Revision information X20BC8084 Version 2.5.4.0: ID: 540315 / Support ID: 400202320 BC sporadically not going into Operational due to X2X-bus problems at startup Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(419), 1\9844_2.fw(419), 1\9844_3.fw(419), 1\9844_4.fw(419) Version 2.5.3.0: ID: 523470 / Support ID:400205694 safety modules not switching to operational state SDO streaming connection via UDP is not always established when PLC and SafeLogic arebooted together. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(417), 1\9844_2.fw(417), 1\9844_3.fw(417), 1\9844_4.fw(417) Version 2.5.2.0: ID: 493885 / Support ID: 400103115, 400101850, 400154063, 400190752 First POWERLINK UDP ASnd SDO transfert after long time takes up to 5s. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(415), 1\9844_2.fw(415), 1\9844_3.fw(415), 1\9844_4.fw(415) Version 2.5.0.0: ID: 468060/ Support ID: 400178654 Safety modules in connection with PLK BCs, with only input datapoints, are not initialized.by SL Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468065 optimization of X2X FW updates Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468070 / Support ID: 400177243 X2X FW update of several X2X modules is not working Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 468530 CiR support Channel description changed: No Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(413), 1\9844_2.fw(413), 1\9844_3.fw(413) Version 2.3.0.0: ID: 454760 AS, System Designer support: cable redundancy Channel descriptionchanged: No Configuration description changed: No Firmware changed:No ID: 460105 / Support ID: 400168329 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 460225 / Support ID: 400150525 Error 114834 "Fehler interner SLX-Kommandokanal" bei CPU PowerCycle wenn SLX hinter BC Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 466675 Module documentation revised Data sheet V 2.32 Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(411), 1\9844_2.fw(411), 1\9844_3.fw(411) Version 2.2.1.0: ID: 449590 Error when running X20BC8084 (Rev. < G0) in base module X20BB80 Correction with new firmware Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(401), 1\9844_2.fw(401), 1\9844_3.fw(401) Version 2.2.0.0: ID: 439100 / Support ID: 400150496 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 439205 / Support ID: 400128436 I/O modules behind POWERLINK bus controllers no longer achieving Operational mode after multiple power-on cycles Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(400), 1\9844_2.fw(400), 1\9844_3.fw(400) Version 2.1.0.0: ID: 404490 X2XLink-BC: StationAtBusEnd does not change, when empty backplanes are added or removed. When emptybackplanes are plugged or unplugged on the end of the X2XLink thediagnostic data point "StationAtBusEnd" die not change. The data point die change when IO Modules were removed or added. A new handshake between Automation Runtimeand firmware was implemented to update the "StationAtBusEnd" faster. The sameproblem also occurs with modules where the X2XLink is supplied with power, but the supply for the IO is missing. Channel description changed: Yes Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(300), 1\9844_2.fw(300), 1\9844_3.fw(300) Version 2.0.0.0: ID: 390280 / Support ID: 400129274 Uncommon X2X settings causepermanent boot of bus controller Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(210), 1\9844_2.fw(210), 1\9844_3.fw(210) Version 1.3.7.0: ID: 376980 With special constructions it could be that stations will be lost. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(174), 1\9844_2.fw(174), 1\9844_3.fw(174) Version 1.3.6.0: ID: 326655 Link-Selektor funktion upgraded Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware:1\9844_1.fw(169), 1\9844_2.fw(169), 1\9844_3.fw(169) Version 1.3.5.0: ID: 310790 / Support ID: 400097674 POWERLINK V1: Bug-fix for Up/Downgrade POWERLINK V1 FW upgrade problem could be accored after PowerOn beginning with HW- Upgrade Version 1.3.1.0 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 311025 / Support ID: 400051206 Expansion: Link- selector flag New datapoints:<br/>- RedundancyFirstLinkState<br/>- RedundancySecondLinkState Channel description changed: Yes Configuration description changed: Yes Firmware changed: No Firmware: 1\9844_1.fw(168), 1\9844_2.fw(168), 1\9844_3.fw(168) Version 1.3.4.0: ID: 305155 / Support ID: 400094368 ACOPOSmulti with SafeMC, asynchronous communication lost When there was a high load on the CPU, asynchronous communicationto the buscontroller was interrupted. Restarting the boscontroller restored communication. Loss of asynchronous communication caused the safety-IO to stop. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(167), 1\9844_2.fw(167), 1\9844_3.fw(167) Version 1.3.3.0: ID: 298990 / Support ID: 400090781 Problem with FW-Update of IO modules on Powerlink buscontrollers The firmware update of IO modules does not work in certain configurations. Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(165), 1\9844_2.fw(165), 1\9844_3.fw(165) Version 1.3.2.0: ID: 289020 Certain X2X configurations don't work In very rare I/O constellations, the X2X modules don't start Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 291455 Upgrade 1.3.1.0 on X20BC8084 to revision E0 may cause problems Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(164), 1\9844_2.fw(164), 1\9844_3.fw(164) Version 1.3.0.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277180 Support of 'Multiple Asynchronous Send' Channel description changed: No Configuration description changed: No Firmware changed: Yes ID: 277750 New X2X datapoints - NettimeOffsetX2X and NettimeX2X Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_1.fw(160), 1\9844_2.fw(160), 1\9844_3.fw(160) Version 1.2.1.0: ID: 271200 Upgraded Kabelredundanz support Hardwarevariant 3 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(154), 1\9844_2.fw(154) Version 1.2.0.0: ID: 265540 Optimation of Kabelredundancy (Link Selector) ; Update behavior on X2X bus improved - optimation of Kabelredundancy (Link Selector) - faster updating of modules with big FW files on the X2X bus of the BC - new objects: 20A3h, 2000h/9 and 20F0h/31 Channel description changed: Yes Configuration description changed: Yes Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.9.0: ID: 220450 Extensions and Bugfixes - Combination of PollResponse-Chaining and PollRequest-Synchronization did not work correctly (A&P 218765) - Network-Failure-Detection did not work when BC_RedundancyTxMode_U8 = 1 Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_2.fw(146) Version 1.0.8.0: ID: 218545 Extensions and Bugfixes - Firmware-Version is transferred via IdentResponse in the first 4 bytes ofthe field VendorSpecificExt1 - Support of PollResponse-Chaining Channel description changed: No Configuration description changed: No Firmware changed: Yes Firmware: 1\9844_1.fw(145) Version 1.0.4.0: ID: 183390 New info-/diagnostic data points, new FW 1.39 for signal filter and corrections New info-/diagnostic data points in HWC, new FW 1.39 for signal filter and corrections Channel description changed: No Configuration description changed:No Firmware changed: No Firmware: 1\9844_1.fw(141) Version 1.0.3.0: ID: 173290 First version of the buscontroller with cableredundancy Channel description changed: No Configuration description changed: No Firmware changed: No Firmware: 1\9844_1.fw(138) |