EN ISO 13849-1:2015
|
|
MTTFD per channel
|
100 years if the relay channel is used individually, 390 years if 2 relay channels are connected in series
|
Mission time
|
Max. 20 years
|
IEC 61508:2010, EN 62061:2013
|
|
PFH / PFHd
|
|
Module
|
<2.7*10-7 if the relay channel is used individually, <5.4*10-9 if 2 relay channels are connected in series
|
openSAFETY wired
|
Negligible
|
openSAFETY wireless
|
<1*10-14 * Number of openSAFETY packets per hour
|
PFD per channel
|
<5.6*10-4 if the relay channel is used individually, <1*10-4 if 2 relay channels are connected in series
|
Proof test interval (PT)
|
20 years
|
Safe relay channels
|
|
EN ISO 13849-1:2015
|
|
Category
|
KAT 1 if the relay channel is used individually, KAT 4 if 2 relay channels are connected in series
|
PL
|
PL c if the relay channel is used individually, PL e if 2 relay channels are connected in series
|
B10d
|
|
DC1, 24 VDC
|
2 A / 1,800,000 4 A / 1,000,000
|
DC13, 24 VDC
|
2 A / 121,400 4 A / 120,000
|
IEC 61508:2010, EN 62061:2013
|
|
SIL CL
|
SIL 1 if the relay channel is used individually, SIL 3 if 2 relay channels are connected in series
|