DWL@DWL10000292005

Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.7.0.0 * 23/07/2021 2 Mo EXE AS4_HW_X20IF10D1-1.exe
Description V4.0 HW Upgrade (X20IF10D1-1)

Revision information X20IF10D1-1

Version 1.7.0.0:

ID:
Adaptations for Automation Studio 4.11
Channel description changed: no
Configuration description changed: yes
Firmware changed: no

Version 1.6.1.0:

ID: 721875
Expansion: Operation behind an X20(c)EM* possible
The module can now also be operated on an X20(c)EM*
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(32), 1\42779_1.fw(13)

Version 1.6.0.0:

ID: 483025
Module documentation revised
Data sheet V1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 627900
Replacement of the interfacecard in AS
"ReplaceHW Modul" works correktly
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 666300
IO mapping of the configured EtherNet/IP adapter is shown correctly.
IO mapping of the configured EtherNet/IP adapter is shown correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(32), 1\42779_1.fw(13)

Version 1.5.0.0:

ID: 644055 / Support ID: 400244211
New Firmware
Problem with "unconnected message handling" was fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(30), 1\42779_1.fw(13)

Version 1.4.0.0:

ID: 598095 / Support ID: 400244211
New Firmware
Problem with "unconnected message handling" was fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(29), 1\42779_1.fw(13)

Version 1.3.1.0:

ID: 469100
netX configuration module name can be defined for X20IF10D1-1 in AS 4 at SGC CPU
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(27), 1\42779_1.fw(12)

Version 1.3.0.0:

ID: 396810
EthernetIP master(X20IF10D1-1) only controls 12 slaves
Error fixed in Hilscher FW version 2.8.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 465630
insert ModulOK
Insert ModulOK from AR4.25
Channel description changed:No
Configuration description changed: Yes
Firmware changed: No

ID: 465635
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel descriptionchanged: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(26), 1\42779_1.fw(12)

Version 1.2.1.0:

ID: 357120
Dynamic configuration
The name of the generatednetX module can be freely assigned in order to enable a dynamic configurationof netX modules in AR.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.2.0.0:

ID: 283615
New firmware: ODVA certification
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.1.1.0:

ID: 268245
Input data of Ethernet/IP slaves is no longer being transferred
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(17), 1\42779_1.fw(12)

Version1.1.0.0:

ID: 257440
Vendor ID changed
Module notifies now with the B&R Vendor ID
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(15), 1\42779_1.fw(12)

Version 1.0.1.0:

ID: 239190
Interface module EtherNet/IP Scanner, first version
Interface module EtherNet/IP Scanner, first version
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(13), 1\42779_1.fw(12)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.6.0.0 * 15/09/2020 2 Mo EXE AS4_HW_X20IF10D1-1.exe
Description V4.0 HW Upgrade (X20IF10D1-1)

Revision information X20IF10D1-1

Version 1.6.0.0:

ID: 483025
Module documentation revised
Data sheet V1.22
Channel description changed: No
Configuration description changed: No
Firmware changed: No

ID: 627900
Replacement of the interfacecard in AS
"Replace HW Modul" works correktly
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 666300
IO mapping of the configured EtherNet/IP adapter is shown correctly.
IO mapping of the configured EtherNet/IP adapter is shown correctly.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(32), 1\42779_1.fw(13)

Version 1.5.0.0:

ID: 644055 /Support ID: 400244211
New Firmware
Problem with "unconnected message handling" was fixed.
Channel description changed: No
Configurationdescription changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(30), 1\42779_1.fw(13)

Version 1.4.0.0:

ID: 598095 / Support ID: 400244211
New Firmware
Problem with "unconnected message handling" was fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(29), 1\42779_1.fw(13)

Version 1.3.1.0:

ID: 469100
netX configuration module name can be defined for X20IF10D1-1 in AS 4 at SGC CPU
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(27), 1\42779_1.fw(12)

Version 1.3.0.0:

ID: 396810
EthernetIP master(X20IF10D1-1) only controls 12 slaves
Error fixed in Hilscher FW version 2.8.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 465630
insert ModulOK
Insert ModulOK from AR4.25
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 465635
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time(CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(26), 1\42779_1.fw(12)

Version 1.2.1.0:

ID: 357120
Dynamic configuration
The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR.
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.2.0.0:

ID: 283615
New firmware: ODVA certification
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.1.1.0:

ID: 268245
Input data of Ethernet/IP slaves is no longer being transferred
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(17), 1\42779_1.fw(12)

Version 1.1.0.0:

ID: 257440
Vendor ID changed
Module notifies now with the B&R Vendor ID
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(15), 1\42779_1.fw(12)

Version 1.0.1.0:

ID: 239190
Interface module EtherNet/IP Scanner, first version
Interface module EtherNet/IP Scanner, first version
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(13), 1\42779_1.fw(12)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.5.0.0 * 20/05/2019 2 Mo EXE AS4_HW_X20IF10D1-1.exe
Description V4.0 HW Upgrade (X20IF10D1-1)

Revision information X20IF10D1-1

Version 1.5.0.0:

ID: 644055 / Support ID: 400244211
New Firmware
Problem with "unconnected message handling" was fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(30), 1\42779_1.fw(13)

Version 1.4.0.0:

ID: 598095 / Support ID: 400244211
New Firmware
Problem with "unconnected message handling" was fixed.
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(29), 1\42779_1.fw(13)

Version 1.3.1.0:

ID: 469100
netX configuration module name can be defined for X20IF10D1-1 in AS 4 at SGC CPU
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(27), 1\42779_1.fw(12)

Version 1.3.0.0:

ID: 396810
EthernetIP master(X20IF10D1-1) only controls 12 slaves
Error fixed in Hilscher FW version 2.8.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 465630
insert ModulOK
Insert ModulOK from AR4.25
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 465635
FDT/DTM Cycle Time change
Change parameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(26), 1\42779_1.fw(12)

Version 1.2.1.0:

ID: 357120
Dynamic configuration
The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.2.0.0:

ID: 283615
Newfirmware: ODVA certification
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.1.1.0:

ID: 268245
Input data of Ethernet/IP slaves is no longer being transferred
Channeldescription changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(17), 1\42779_1.fw(12)

Version 1.1.0.0:

ID: 257440
Vendor ID changed
Module notifies now with the B&R Vendor ID
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(15), 1\42779_1.fw(12)

Version 1.0.1.0:

ID: 239190
Interface module EtherNet/IP Scanner, first version
Interface module EtherNet/IP Scanner, first version
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(13), 1\42779_1.fw(12)
Version Langue
Système d'exploitation
Date
Taille
Type Téléchargement
1.3.1.0 * 07/03/2016 909 Ko EXE AS4_HW_X20IF10D1-1.exe
Description V4.0 HW Upgrade (X20IF10D1-1)

Revision information X20IF10D1-1

Version 1.3.1.0:

ID: 469100
netX configuration module name can be defined for X20IF10D1-1 in AS 4 at SGC CPU
Channel description changed:No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(27), 1\42779_1.fw(12)

Version 1.3.0.0:

ID: 396810
EthernetIP master(X20IF10D1-1) only controls 12 slaves
Error fixed in Hilscher FW version 2.8.0.0
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes

ID: 465630
insert ModulOK
Insert ModulOK from AR4.25
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No

ID: 465635
FDT/DTM Cycle Time change
Changeparameter name "Cycle time [µs]" to "Data exchange time (CPU-netX) [µs]"
Channel description changed: No
Configuration description changed: Yes
Firmware changed: No
Firmware: 1\42779a1.fw(26), 1\42779_1.fw(12)

Version 1.2.1.0:

ID: 357120
Dynamic configuration
The name of the generated netX module can be freely assigned in order to enable a dynamic configuration of netX modules in AR.
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.2.0.0:

ID: 283615
New firmware: ODVA certification
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(18), 1\42779_1.fw(12)

Version 1.1.1.0:

ID: 268245
Input data of Ethernet/IP slaves is no longer being transferred
Channel description changed: No
Configuration description changed: No
Firmware changed: No
Firmware: 1\42779a1.fw(17), 1\42779_1.fw(12)

Version 1.1.0.0:

ID: 257440
Vendor ID changed
Module notifies now with the B&R Vendor ID
Channel description changed: No
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(15), 1\42779_1.fw(12)

Version 1.0.1.0:

ID: 239190
Interface module EtherNet/IP Scanner, first version
Interface module EtherNet/IP Scanner, first version
Channel description changed: Yes
Configuration description changed: No
Firmware changed: Yes
Firmware: 1\42779a1.fw(13), 1\42779_1.fw(12)
Loading