24 VDC supply voltage and grounding (3 wires), SELV
Enable switch
Direct connection between enable switch and monitoring device (6 wires) (2 wires not used on the MP40/50 and MP7x00)
Connector
Type
Receptacle for push-pull locking mechanism
Operating conditions
Shield attenuation
Per IEC 60096-1, Amendment 2
Flame-retardant
Per IEC 60332-1 and VW1 / FT1 in accordance with C-UL
Oil and hydrolysis resistance
Per VDE 0282-10
Ambient conditions
Temperature
Moving
-5 to 60°C
Static
-20 to 80°C
Mechanical properties
Dimensions
Length
2 m ±0.05 m
Diameter
10 mm
Bend radius
Min. 60 mm
Weight
153 g/m
Tension
Max. 140 N
Número de material:
5CAMPC.0020-10
Descripción:
A crossover control cabinet cable is required for the wiring inside the control cabinet. The pinout of the Ethernet connector (crossover) makes it possible to connect directly to a B&R controller (e.g. X20CPxxxx). For other devices, e.g. Ethernet hubs, it is important to ensure that they support crossover of the RX and TX lines.